841 - Heating oil treatment systems
Information
Suppliers
Documents
Sales representatives
STEAM AND HEAT SOLUTIONS
www.parat.no
STEAM AND HEAT SOLUTIONS
www.parat.no
Show map
Supplier name
Parat Halvorsen A-S
NORWAY
Product name
Product description
ELECTRICAL CIRCULATION STEAM BOILERS
ECS - ELECTRICAL CIRCULATION STEAM BOILERS The PARAT Electrical circulation steam boiler was designed to meet the request for a modular and easy to install alternative to MGO fuel for auxiliary boilers on existing vessels in operation. By integrating the ECS in your boiler you have the option to maintain your steam pressure from an electrical power source (shore power, spare generator power etc.). The unit can be installed on any kind of existing steam boiler system and is also a good solution for newbuilds where increased fuel flexibility for the steam system is required. The electrical cabinet is not directly connected to the boiler unit. This ensures a low temperature in the electrical components. The cabinet is standardized, and type approved according to the NEK 400. Included are fuses, contactors and complete safety system. As an option the unit can be delivered with a main power switch. The boiler unit is designed for vertical or horizontal installation depending on the layout and space availability around the main auxiliary boiler. Inlet and outlet connections to main boiler will be done on site. The ECS can be delivered as a standard modular unit in capacities up to 400kW, which is equivalent to 600kg steam per hour. Larger capacities can be provided upon request. ELECTRICAL STEAM BOILERS The Parat Electrical element boiler can be delivered with capacity up to 5000 kW. With our 40 years of experience in marine boilers PARAT has landed on a rugged design that fulfills all class requirements. The electrical element boiler is very compact, and one of the greatest advantages with this product is the possibility of low load regulation, down to 15 kW. No smoke stack is needed, thus saving space and costs. The electrical cabinet is not directly connected to the boiler. This ensures a low temperature in the electrical components. The cabinet is standardized, and type approved according to NEK 400. Included in the cabinet is the main switch, fuses, contactors and a complete safety and control system. This system is based on a Siemens PLC SIMATIC S7 system with a touch panel for local operation. Communication with the main control system is possible, via analog and digital signals to bussystems as PROFIBUS and MODBUS. The safety system is independent from the PLC system. For vessels with ORO operation class, Parat has developed a successful package containing a heat exchanger for the hot water system and steam lances for heating of the ORO tanks. The patended Parat MEL-C was developed to meet the demand for a compact and flexible system that allows the operator to use one boiler system for both steam and hot water production. In normal operation the boiler generates hot water at an operating temperature of 90oC. When there is a requirement for steam production the water level in the boiler is reduced to provide a sufficient steam separation area. Hot water production is maintained separately by an electric heater in a bypass circuit. The MEL-DC was developed to enable connection to direct current power supply. It is based on our standard MEL low Voltage boiler but with specialized immersion heaters and control panel.
Click to view product documents
Marine Boilers
pdf
ECS Electrical Circulation Steam Boilers
pdf
Offshore Heating Solutions
pdf
HOT WATER BOILERS
MVH Vertikal Hot Water Boiler The PARAT MVH is a vertical smoke tube hot water boiler. Vertical design gives the smallest possible footprint and increases the flexibility when placing the boiler in a limited space area. The oil burner is mounted at the side, easy accessible for inspection and maintenance. The combustion chamber is well dimensioned for burning of MDO and HFO. The boiler is delivered as a complete unit, insulated and preassembled with all valves and instruments, oil burner and control panel. The Hot water boiler can be delivered with integrated electrical heating elements. The immersion heaters are installed along the side of the boiler shell for easy access and maintenance. The control system is designed to achieve an unmanned engine room. The system is fully automatic and operates with electronic controllers and electric/pneumatic actuators. The panel is mounted on the boiler side. All control of the boiler panel is operated from the local touch screen. Boiler PLC can be connected to main control system by standard ethernet/profibus/modbus communication.
Click to view product documents
Marine Boilers
pdf
MVH Vertical Hot Water Boiler
pdf
Offshore Heating Solutions
pdf
Thermal Tec AS
NORWAY
Product name
Product description
EXHAUST GAS BOILERS
Clayton Exhaust Gas Boilers The Clayton Heat Recovery Boiler operates on the same tried and tested principle as the world famous Clayton Steam Generator It is therefore the most compact, efficient, responsive and safest means of producing high quality steamor hot water from waste gas streams
841 - Heating o...
Sign in
Read more
Select language:
Arabic
Bulgarian
Catalan
Chinese_Simplified
Chinese_Traditional
Czech
Danish
Dutch
English
Estonian
Persian_Farsi
Finnish
French
German
Greek
Haitian_Creole
Hebrew
Hindi
Hungarian
Indonesian
Italian
Japanese
Korean
Latvian
Lithuanian
Hmong_Daw
Norwegian
Polish
Portuguese
Romanian
Russian
Slovak
Slovenian
Spanish
Swedish
Thai
Turkish
Ukrainian
Vietnamese
0 item(s) in cart